| Nominal diameter of wire rope(mm) | Minimum Thickness(mm) | The least broken rate (KN) | Elongation rate no bigger than (%) | Diameter of steel wire | Referable weight of zinc-plating wire rope(Kg/100m) | ||||
| d1 | Permitted diameter deviation | d2 | Permitted diameter deviation | Elestic elongation | Surplus elongation | ||||
| 1.2 | +0.15 0 | 1.8 | +0.2 -0.1 | 0.15 | 1.45 | 0.8 | 0.2 | 0.24 | 0.705 |
| 1.6 | +0.16 0 | 2.2 | 2.58 | 0.32 | 1.254 | ||||
| 2.0 | +0.20 0 | 2.6 | 4.04 | 0.40 | 1.967 | ||||
| 2.5 | +0.24 0 | 3.1 | 6.00 | 0.50 | 3.065 | ||||
| 3.0 | +0.24 0 | 3.8 | 0.2 | 8.63 | 0.60 | 4.405 | |||
| 3.5 | +0.28 0 | 4.3 | 11.79 | 0.70 | 6.016 | ||||
| Nominal diameter of wire rope(mm) | Minimum Thickness(mm) | The least broken rate (KN) | Elongation rate no bigger than (%) | Diameter of steel wire | Referable weight of zinc-plating wire rope(Kg/100m) | ||||
| d1 | Permitted diameter deviation | d2 | Permitted diameter deviation | Elestic elongation | Surplus elongation | ||||
| 1.2 | +0.15 0 | 1.8 | +0.2 -0.1 | 0.15 | 1.26 | 0.9 | 0.2 | 0.14 | 0.656 |
| 1.6 | +0.16 0 | 2.2 | 2.17 | 0.18 | 1.134 | ||||
| 2.0 | +0.20 0 | 2.6 | 3.21 | 0.22 | 1.673 | ||||
| 2.5 | +0.24 0 | 3.1 | 5.25 | 0.28 | 2.737 | ||||
| 3.0 | +0.24 0 | 3.8 | 0.2 | 7.79 | 0.34 | 4.061 | |||
| 3.5 | +0.28 0 | 4.3 | 10.68 | 0.40 | 5.646 | ||||
| 4.0 | +0.32 0 | 4.8 | 12.95 | 0.45 | 7.086 | ||||